The electrical cabinet which is included in MMIS is very important to operate for nuclear power plants. Though instruments installed in electric l cabinets have a short cycle to improve performance or to fix errors, it is hard to remove or change after electrical cabinets are installed because it should operate for 40 years. When partially cracked parts of an electrical cabinet are found, the structural integrity should be performed to assess whether there are any effects on the operation of the nuclear power plants. Therefore, in this study, considering some cases of partially cracked cabinets occurring in the area where the stress is concentrated, it was evaluated on the assumption that it occurred several places at the same time from a conservative point of view. According to use the test results, the consistency of the numerical analysis model was improved. The values of maximum stress were assessed by spectrum analysis. And then, the structural integrity and seismic performance evaluation were performed. As a result of this study, it was checked that the evaluations performed was not satisfactory when partially cracks of the electric cabinet.
원자력발전소 계측제어설비의 국산화에 따라 전기외함은 발전소 운영에 있어서 매우 중요한 역할을 한다. 전기외함 내부에 설치된 계전기는 성능 개선과 고장 등으로 인해 매우 짧은 교체 주기를 갖는데 반해 전기외함은 초기 설치 이후로 40여년동안 계속 운전하므로 교체하기 어려운 구조물이다. 따라서 원전 운영 중 국부적으로 균열이 발생한 경우 이를 즉각 확인하여 구조적 건전성 평가를 수행하여 원전 운영에 영향이 없는지 평가하여야 한다. 따라서 본 연구는 응력이 집중되는 부위에서 국부적인 균열이 발생할 경우를 고려하였으며 보수적인 관점에서 여러 군데가 동시에 발생하는 것을 가정하여 평가하였다. 시험결과를 이용하여 수치해석모델의 정합성을 높이고 스펙트럼해석을 이용하여 구조적 건전성 평가와 내진성능평가를 수행하였다. 본 연구 결과로서 전기외함에 국부적인 균열이 발생할 경우 수행된 평가에 만족하지 못한 것으로 확인되었으며 이는 추후 원전 운영 중 유사한 균열이 발생할 경우 참고자료로서 활용 가능할 것으로 판단된다.