An experimental study on the effect of filling ratio on maximum heat input of pulsating heat pipes in a horizontal orientation was conducted for various adiabatic lengths. For this purpose, the filling ratio was varied from 30% to maximum filling ratio with intervals of 10% until the pulsating heat pipes could not be operated. And the adiabatic length was varied from 15mm to 300mm. pulsating heat pipes are made of stainless steel 316 tubes with 1.0 and 1.6 mm inner and outer diameter. R-134a was used as a working fluid. The lengths of the evaporator and condenser are 200 and 300 mm, respectively. It was confirmed that the optimum filling ratio with respect to the maximum heat input increases as the adiabatic length of pulsating heat pipes increases. As the adiabatic length increases, the maximum heat input at the optimal filling ratio decreases. And it has been found that a length limit exists where the pulsating heat pipes cannot work.
다양한 단열부 길이에 대해 충진율이 수평 진동형 히트파이프의 최대 입열량에 미치는 영향에 대한 실험적 연구를 수행하였다. 이를 위해 단열부 길이가 15, 100, 200, 300 mm 인 진동형 히트 파이프에 대해 충진율을 30%에서 10%간격으로 증가시켜 진동형 히트파이프의 작동이 불가능할 때까지 변화시켰다. 진동형 히트파이프는 스테인리스 스틸 316 재질의 1.0, 1.6 mm 내경의 튜브를 이용하여 제작하였으며 작동유체로는 R-134a가 사용되었다. 증발부 및 응축부의 길이는 각각 200, 300 mm 이다. 진동형 히트파이프의 단열부 길이가 길어질수록 최대 입열량에 대한 최적 충진율이 증가하는 것을 확인하였으며 단열부 길이가 길어질수록 최적 충진율에서의 최대 입열량이 감소하는 것을 확인하였다. 또한 진동형 히트파이프가 작동하지 않는 길이 한계를 발견하였다.