서지주요정보
혼합 용매와 전장하에서 이온을 함유하는 고분자 겔의 팽윤 현상 = Swelling behavior of ionic polymer gel in the mixed solvents and under the electric field
서명 / 저자 혼합 용매와 전장하에서 이온을 함유하는 고분자 겔의 팽윤 현상 = Swelling behavior of ionic polymer gel in the mixed solvents and under the electric field / 이원상.
발행사항 [대전 : 한국과학기술원, 1992].
Online Access 제한공개(로그인 후 원문보기 가능)원문

소장정보

등록번호

8003023

소장위치/청구기호

학술문화관(문화관) 보존서고

MCE 92029

휴대폰 전송

도서상태

이용가능(대출불가)

사유안내

반납예정일

리뷰정보

초록정보

In order to examine the electric response of the ionic polymer gel, five types of ionic gel with different compositions were prepared. The degree of ionization of polyion for each samples has been calculated by means of the swelling equation based on Flory-Huggins model. Sample 4 (HSMA: CA: HPVA = 1: 0.1: 0.3, mol) shows the highest ionization magnitude calculated according to the model and sample 3(HSMA: CA: HPVA = 1: 0.1: 0.2, mol), sample 2(HSMA: CA: HPVA = 1: 0.1: 0.1, mol), sample 5(HSMA: CA: HPVA = 1: 0.2: 0.1, mol) and sample 1(HSMA: CA: HPVA = 1: 0.1: 0, mol) follow. This tendency agrees well with the fact that sample 3(HSMA: CA: HPVA = 1: 0.1: 0.2, mol) and sample 4(HSMA: CA: HPVA = 1: 0.1: 0.3, mol) undergo phase transitions in response to changes in solvent compositions for MeOH+water, acetone+water and EtoH+water systems. The results of swelling experiment in mixed solvent(MeOH+water, acetone+ water and EtoH+water mixture) are well fitted with Tanaka model. One of the parameters obtained by this work, f(the number of dissociated conuterions per effective chain) was the larger for sample 4 and sample 3 than the others and which agrees roughly with the degree of ionization, i which was calculated by using Flory-Huggins model. Electric experiments were performed on the three different diameter (0.215, 0.34, 0.5㎝) samples by virtue of putting their samples horizontal or vertical to electrode in the various NaOH concentration (0.02, 0.04, 0.06N) at 5 and 10V. The swelling and shrinking of ionic gel in electric field is mainly controlled by the influence of activity of counter ion. Characteristic swelling and shrinking time increases according to rising the NaOH concentration, for each sample at constant electric voltage. If the other conditions are same, swelling change ratio y(∞) is related with the the polyion quantity for unit volume and characteristic swelling time(τ) is connected with field strength. Sample 3(HSMA: CA: HPVA = 1: 0.1: 0.2, mol) showes better electric behavior judged on high swelling change ratio y(∞). It well agrees with the fact that the degree of ionization for sample 3 calculated previousby is higher than the others. As far as the diameter is concerned, case of 0.34㎝ is best.

서지기타정보

서지기타정보
청구기호 {MCE 92029
형태사항 xi, 64 p. : 삽화 ; 26 cm
언어 한국어
일반주기 저자명의 영문표기 : Won-Sang Lee
지도교수의 한글표기 : 정인재
지도교수의 영문표기 : In-Jae Chung
학위논문 학위논문(석사) - 한국과학기술원 : 화학공학과,
서지주기 참고문헌 : p. 61-62
주제 Polymers.
전기장. --과학기술용어시소러스
고분자. --과학기술용어시소러스
Electric fields.
QR CODE

책소개

전체보기

목차

전체보기

이 주제의 인기대출도서