열적 비평형이 Pressure-Volume-Temperature 측정에 미치는 영향에 관한 실험적 연구 = Experimental study on thermal non-equilibrium effect on Pressure-Volume-Temperature gauging
서명 / 저자 열적 비평형이 Pressure-Volume-Temperature 측정에 미치는 영향에 관한 실험적 연구 = Experimental study on thermal non-equilibrium effect on Pressure-Volume-Temperature gauging / 박하나.
발행사항 [대전 : 한국과학기술원, 2014].
Online Access 원문보기 원문인쇄

소장정보

등록번호

8026205

소장위치/청구기호

학술문화관(문화관) 보존서고

MME 14017

휴대폰 전송

도서상태

이용가능(대출불가)

사유안내

반납예정일

리뷰정보

초록정보

A Pressure-Volume-Temperature (PVT) gauging method is presented to measure volume of cryogenic liquid in a micro-gravity condition due to its simple measuring process and no additional hardware. It needs only pressurant supply tank which is connected to the cryogenic liquid storage tank without leakage. Helium gas is used as pressurant due to non-condensable and lightweight characteristic. It measures volume of inside of the liquid tank and change in mass and density helium in the liquid tank. However, thermodynamic state is not well defined in the liquid tank due to constant vaporization of cryogenic liquid. In this paper, the PVT gauging was experimentally studied when liquid tank is in thermal non-equilibrium and equilibrium condition and verified how to measure pressure and temperature of helium exactly to define thermodynamic state. Experimental system consisted of 0.6 L helium supply tank and 0.5 L flask or 9.2 L metal cryogenic liquid storage tank. The flask was used to verify exact amount of liquid level and low insulation quality effect. The metal tank was used to pressurize more than pressure limitation of the flask. In thermal non-equilibrium condition, effect of cryogenic liquid volume and pressure increment by helium injection was studied. As liquid level lowered, degree of thermal non-equilibrium measured by difference of gas temperature was increased. Nonhomogeneous gas temperature resulted in boil off gas generation which causes inexact measurement of partial pressure of helium. Nevertheless, an exact liquid volume measurement in thermal non-equilibrium condition was obtained as average 1.13 % liquid volume measurement error regardless in amount of liquid in well insulated tank by slow and large helium injection without increasing degree of thermal non-equilibrium. It was observed helium partial pressure was measured exactly when helium partial pressure portion in pressure of the liquid tank due to helium injection was more than 20 %. Low temperature helium injection was not effected in thermal non-equilibrium condition since there was temperature difference between liquid and gas was existed. Thermal equilibrium condition was made by micro-gravity parabolic flight experiment and shaking the liquid tank on the ground. Exact helium temperature was obtained due to no spatial variation in gas temperature. Partial pressure of helium before and after pressurization was exactly measured as difference of pressure of the liquid tank and vapor pressure measured by saturation pressure of gas temperature. Liquid volume measurement error was average 2.6 % in the flight experiment and average -0.9 % in shaking condition. Low temperature helium injection to the liquid tank in thermal equilibrium condition was not effective in measurement accuracy improvement, but less vaporization of cryogenic liquid is expected by lower heat input.

Pressure-Volume-Temperature 측정 방법은 저중력에서 극저온 유체의 부피를 측정하는 방법으로 측정이 간단하고, 추가적인 장비가 필요하지 않다는 장점이 있다. 가압제 공급 용기와 극저온 유체 보관 용기가 누설 없이 연결된 장치에 적용된다. 불응축성이고, 가벼운 헬륨 기체가 가압제로 쓰인다. 액체 부피를 알기 위해, 액체 용기의 부피와 액체 용기 내 헬륨의 질량과 밀도의 변화를 측정한다. 그러나 극저온 액체가 끊임없이 기화하기 때문에 액체 용기 내 열역학적 상태를 정의하기 어렵다. 본 논문에서는 액체 용기가 각각 열적 비평형 상태와 평형 상태 일 때, PVT 측정에 이용하기 위해 헬륨의 압력과 온도를 정확하게 측정할 수 있는 방법을 확인하고, 액체 부피 측정 결과를 비교했다. 실험 장치는 0.6 L 헬륨 공급 용기와 0.5 L 플라스크나 9.2 L 금속 극저온 액체 보관 용기로 구성되었다. 플라스크는 액체의 높이를 정확히 확인하고, 단열 성능이 좋지 않은 영향을 확인하기 위해 사용되었다. 금속 용기는 플라스크의 압력 제한보다 더 많이 가압하기 위해 사용되었다. 열적 비평형 상태에서는 극저온 액체의 양과 헬륨 가압에 의한 압력 증가량의 영향이 실험적으로 비교되었다. 액체의 양이 줄어들수록, 기체 온도의 공간적 차이로 측정된 열적 비평형 정도가 커졌다. 불균일한 기체 온도는 boil off gas 발생을 증가시켜, 헬륨 분압을 정확하게 측정하지 못하게 하였다. 그럼에도 불구하고, 단열이 좋은 액체 용기에 많은 양의 헬륨을 천천히 가압하여 열적 비평형 정도가 증가하지 않도록 했을 때, 열적 비평형 상태에서도 액체의 양에 상관없이 평균 1.1%의 오차로 액체 부피가 정확하게 측정되었다. 이 때 액체 용기 압력에서 헬륨 분압이 차지하는 비중이 20%가 넘어, 헬륨 분압이 정확하게 측정되었기 때문이었다. 반면, 액체 용기 내에 유입되는 열을 줄이기 위해 헬륨을 냉각하여 주입하여도 기체와 액체 사이에 온도 차이가 존재하였기 때문에 액체 부피 측정이 정확하지 않았다. 그리고 액체 용기 내 열적 평형 상태는 저중력 모사 비행 실험과 지상에서 액체 순환 실험을 통해 모사되었다. 공간적으로 기체 온도 차이가 없어, 기체 대표 온도는 정확하게 설정되었다. 액체 용기의 압력과 기체 온도에 해당하는 포화 압력으로 측정된 극저온 액체가 기화한 기체의 분압의 차로 가압 전과 후의 헬륨 분압이 정확하게 측정되었다. 온도와 압력이 정확하게 측정되었기 때문에, 비행 실험에서 평균 2.6%, 순환 실험에서 평균 -0.9%의 오차로 액체 부피가 정확하게 측정되었다. 열적 평형 상태에서 저온 헬륨 주입은 액체 부피 측정 정확도에 영향을 주지는 않았지만, 헬륨 가압으로 액체 용기에 유입되는 열이 적기 때문에 극저온 액체의 증발이 적은 것으로 기대되었다.

서지기타정보

서지기타정보
청구기호 {MME 14017
형태사항 xiii, 140 p. : 삽화 ; 30 cm
언어 한국어
일반주기 저자명의 영문표기 : Ha-Na Park
지도교수의 한글표기 : 정상권
지도교수의 영문표기 : Sang-Kwon Jeong
학위논문 학위논문(석사) - 한국과학기술원 : 기계공학전공,
서지주기 참고문헌 : p. 140
QR CODE

책소개

전체보기

목차

전체보기

이 주제의 인기대출도서