서지주요정보
New type of impactor with varying impaction plate temperature for capturing particulate matters : including PM2.5 and bioaerosols = 충돌판 온도변화를 이용한 새로운 임팩터의 개발 및 연구 : PM2.5 및 바이오미세입자 포집에의 응용
서명 / 저자 New type of impactor with varying impaction plate temperature for capturing particulate matters : including PM2.5 and bioaerosols = 충돌판 온도변화를 이용한 새로운 임팩터의 개발 및 연구 : PM2.5 및 바이오미세입자 포집에의 응용 / Byung-Uk Lee.
발행사항 [대전 : 한국과학기술원, 2003].
Online Access 원문보기 원문인쇄

소장정보

등록번호

8014313

소장위치/청구기호

학술문화관(문화관) 보존서고

DME 03036

휴대폰 전송

도서상태

이용가능(대출불가)

사유안내

반납예정일

리뷰정보

초록정보

Impactors are the most widely used particle size-selective samplers. These are not only sampling devices but also aerosol classifiers. Impactors use the particle inertia to sample and classify aerosols. When an impactor is used, an impaction plate is greased with a coating material to prevent reentrainment and to obtain higher efficiency. However, for bioaerosols, it may be impractical to use a coating material since it can cause viability loss and contamination of bioaerosols. And the work of coating is inaccurate and burdensome. However, without the coating material, the performance of an impactor is inadequate - a problem which necessitates this research. In this study, we experimentally show the effect of impaction plate temperature change on the impactor performance. The impaction plate was cooled or heated with the thermoelectric module in the impactor. The temperature of the impaction plate was then monitored by the thermocouple connected to the impaction plate. Comparisons among the results reveal that cooling the impaction plate makes the impactor collection efficiency higher and the re-entrainment lower. Therefore, the collection efficiency curve becomes steeper, illustrating the increased effectiveness. To elucidate the reason of these phenomena, we designed two kinds of experiments and got the reasonable results. It was found that the condensation effect was the dominant mechanism in reducing rebounce in the cooled plate impactor rather than the thermophoresis effect. And this kind of impactor could be applied to PM2.5 classification. To show the application of this kind of impactor, we sampled the bioaerosols by this impactor. E.coli and B.subtilis bacteria bioaerosols were used for the experiments. Based on the study, a new type of impactor with a thermoelectrically cooled plate is proposed, and is demonstrated to work well in these experimental conditions.

서지기타정보

서지기타정보
청구기호 {DME 03036
형태사항 xi, 73 p. : 삽화 ; 26 cm
언어 영어
일반주기 저자명의 한글표기 : 이병욱
지도교수의 영문표기 : Sang-Soo Kim
지도교수의 한글표기 : 김상수
수록잡지명 : "The effect of varying impaction plate temperature on impactor performance : experimental studies. ". Journal of aerosol science, v.33, pp.451-457 (2002)
수록잡지명 : "Hygroscopic growth of E.coli and B.subtilis bioaerosols". Journal of aerosol science , v.33, pp.1721-1723 (2002)
학위논문 학위논문(박사) - 한국과학기술원 : 기계공학전공,
서지주기 Reference : p. 57-59
QR CODE

책소개

전체보기

목차

전체보기

이 주제의 인기대출도서