KSTAR 초기 플라즈마 진단을 위한 ECE 헤테로다인 수신기 설계 및 제작 = Design and fabrication of an ECE heterodyne radiometer for KSTAR 1st plamsa
서명 / 저자 KSTAR 초기 플라즈마 진단을 위한 ECE 헤테로다인 수신기 설계 및 제작 = Design and fabrication of an ECE heterodyne radiometer for KSTAR 1st plamsa / 정승호.
발행사항 [대전 : 한국과학기술원, 2003].
Online Access 원문보기 원문인쇄

소장정보

등록번호

8014235

소장위치/청구기호

학술문화관(문화관) 보존서고

DPH 03001

휴대폰 전송

도서상태

이용가능(대출불가)

사유안내

반납예정일

리뷰정보

초록정보

This paper presents the design of an ECE diagnostic system to measure the electron temperature and its profiles for initial operation of KSTAR. First, we discuss the feasibility of ECE heterodyne radiometer diagnostic for the $1^st$ plasma ($B_γ$=1.5T, $R_0$=1.6m, a=0.3m) of KSTAR during the experiments of ECH at 84GHz. From an evaluation of the density range, the optical thickness, and the harmonic overlap, it is shown that the $2^nd$ harmonic X-mode is the most suitable choice. The designed E-band radiometer operates in single side band and has an 8-ch power divider and filter banks to cover frequency range of 70GHz-84GHz. The center frequencies, which are those of each IF channel, are the frequencies of 4-18GHz with 2GHz step. The 3dB bandwidth of band pass filter in IF channel is 1GHz. The noise temperature, the sensitivity and the expected output signal of the radiometer are estimated. The measured noise temperature is about 1eV, the minimum detectable limit is 1.5% of the plasma temperature. The time resolution of the 10ms and the spatial resolution less than 5cm are achieved. The spatial resolution includes the Doppler and relativistic broadening. The KSTAR is equipped with fully superconducting magnet system and thus the vacuum vessel is covered with a large cryostat, which results in long view ports around the vacuum vessel. So it makes the optimization of the optical system difficult. The optical system, which is designed by quasi-optical method, is composed of a metal lens, a dielectric lens, and a scalar horn antenna. A metal lens has focal lengths that are depending on frequencies. This feature is one of the advantages of using the metal lens, since it places the focus approximately where the electron cyclotron emission occurs. Radii of beam waists in the plasma region are 10mm to 15mm corresponding frequency range of 72-84GHz.

서지기타정보

서지기타정보
청구기호 {DPH 03001
형태사항 iii, 115 p. : 삽화 ; 26 cm
언어 한국어
일반주기 저자명의 영문표기 : Seung-Ho Jeong
지도교수의 한글표기 : 장홍영
지도교수의 영문표기 : Hong-Young Chang
수록잡지명 : "Design of a heterodyne electron cyclotron emission system on KSTAR". Review of scientific instruments, v.74 no.3, pp.1-4 (2003)
학위논문 학위논문(박사) - 한국과학기술원 : 물리학과,
서지주기 참고문헌 : p. 111-115