서지주요정보
Polyetherimide 접착제의 표면 처리에 따른 MCM-D 계면 접착력 및 고온고습 신뢰성 변화에 관한 연구 = A study on the effect of polyetherimide surface treatment on the adhesion and high temperature/high humidity reliability of MCM-D interface
서명 / 저자 Polyetherimide 접착제의 표면 처리에 따른 MCM-D 계면 접착력 및 고온고습 신뢰성 변화에 관한 연구 = A study on the effect of polyetherimide surface treatment on the adhesion and high temperature/high humidity reliability of MCM-D interface / 윤현국.
발행사항 [대전 : 한국과학기술원, 1999].
Online Access 원문보기 원문인쇄

소장정보

등록번호

8010336

소장위치/청구기호

학술문화관(문화관) 보존서고

MMS 99049

휴대폰 전송

도서상태

이용가능(대출불가)

사유안내

반납예정일

리뷰정보

초록정보

The adhesion strength and high temperature/high humidity reliability of Polyetherimide (PEI) adhesive on silicon wafer after being treated by RIE, Al-chelate system adhesion promoter, and perchloric acid was investigated, and the relationship between adhesion strength and high temperature/high humidity reliability was explained by various adhesion mechanism theories. 180°peel test and 「85℃85%」humidity test were performed for the initial adhesion strength and high temperature/high humidity reliability tests. For investigating microscopic surface effect SEM, AFM, DI-Water contact angle, AES and ATR-FT-IR studies were carried out. To investigate RIE effect, PEI was treated with 170 mtorr 40 sccm O2 and 200 Watt RIE for 1, 2, 3, 5 min, and laminated at 300 ℃ for 1 hr. The initial peel strength increased slightly from 1.6 kg/cm for the first 2 min, but decresed after 3 min. High temperature/high humidity resistivity decreased rapidly by RIE etching. RIE treatment on PEI affected on both of roughness and hydrophilicity to increase. Al-chelate adhesion promoter was coated by spinning on silicon wafer for 3000 rpm 30 sec and cured at 320 ℃ for 4 min. The initial peel strength showed no effect of adhesion promoter treatment, but high temperature/high humidity resistivity increased remarkably. Al-chelate adhesion promoter did not affect the roughness but increased hydrophilicity. Perchloric acid etching on PEI resulted in decrement of both initial peel strength and high temperature/high humidity reliability. The roughness was not changed by perchloric acid etching. Hydrophilicity was varied with time and temperature. The carbonyl C=O bonding increased slightly and the imide C-N bonding decreased. There was no clear evidence that perchloric acid treatment increased peel strength as was in the metal/polyimide interface research by other researchers. As a summary, the increment of surface roughness by RIE also increased slightly initial peel strength but increment of hydrophilicity by RIE decreased rapidly high temperature/high humidity reliability. Al-chelate adhesion promoter decreased hydrophilicity, which caused high temperature/high humidity resistivity strengthening. The perchloric acid treatment showed no clear effects. The mechanisms of initial peel strength increment and of high temperature/high humidity reliability have to be further investigated.

서지기타정보

서지기타정보
청구기호 {MMS 99049
형태사항 iv, 38 p. : 삽화 ; 26 cm
언어 한국어
일반주기 저자명의 영문표기 : Hyun-Gook Yoon
지도교수의 한글표기 : 백경욱
지도교수의 영문표기 : Kyung-Wook Paik
학위논문 학위논문(석사) - 한국과학기술원 : 재료공학과,
서지주기 참고문헌 : p. 37-38