The effects of various variables on retention volumes were studied and partition coefficient, separation factor, column efficiency and heat of solution were obtained by the analytical chromatography.
The feed materials were diethylether, dimethoxymethane and dichloromethane with similar boiling points. The variables were mixture volume, % loading, particle size, column length, and column temperature.
The relation of partition coefficient to column temperature could be expressed as the following exponential term.
$K = K_o exp (-ΔH_s/RT)$
The HETP increased almost linealy with sample volume and other effects of various variables were considered.
Frontal analysis was performed using ID-1 cm glass column and the column efficiency for each experimental condition was calculated. Comparisons between analytical and preparative chromatography were made. HETP increased with temperature and flow rate which showed the same tendency between them.
Based on the above obtained results, the experimental of simulated moving bed was performed. The ratio of outlet to inlet concentration was 1.6 and 0.4 for DEE and DCM respectively.
분석용 크로마토그래피를 이용하여 체류 부피에 영향을 미치는 변수들을 고찰하였고, 분배계수, 분리도, 관효율, 용해열 등을 구하였다.
실험에 사용된 물질은 비점이 비슷한 에테르, 메톡시 메탄, 클로로메탄이다. 실험 변수로는 물질의 양, 입자의 크기, 관의 온도, Stationary liquid 의 양, 관의 길이 등이다.
분배 계수와 관의 온도의 관계는 다음과 같이 지수항으로 표시할 수 있었다.
$K = K_o exp (- ΔH_s/RT)$
HETP 는 물질의 양에 따라 거의 직선적으로 증가하였다.
내경 1cm 유리관을 이용하여 frontal analysis 를 했고 여기서 각 경우에 대한 이론 단수를 구하여 HETP 를 계산하였다. HETP 는 기체유량과 온도에 따라 증가하였고, 이 결과는 분석용 크로마토그래피와 같은 경향을 보였다.
위에서 얻은 실험결과를 기초로 하여, Simulated moving bed 실험을 하였다. 원료의 들어가는 농도와 나가는 농도의 비율이, 에테르와 클로로메탄일때 각각 1.6, 0.4 였다.