Axial dispersion coefficients have been measured in the continuous phase of a 10.8cm diameter pulsed plate extraction column. The measurements were made by observing the course of an instaneous chemical reaction between acid and base in the continuous phase, using phenolphthalein as indicator.
Two different plates were imployed, namely perforated and star-shaped plates. The air pulsing is carried out by means of solenoid valves and a timing controller. The pulsation amplitude and frequency were varied from 0.5 to 8.0 cm and from 0.5 to 2.0 Hz, respectively.
Axial dispersion coefficient increased with increasing amplitude and frequency of pulsation, with decreasing free opening fraction of the plate and plate spacing distance. The flow velocities of each phase and the plate thickness have no significant effects on the axial dispersion.
The data have been correlated in terms of amplitude, frequency, plate spacing, plate free area.
맥동 추출탑내에서 일어나는 축방향 물질분산에 미치는 여러인자들의 영향을 살펴보고, 일반적으로 적용될수 있는 실험 상관식을 구하는 것이 본 연구의 목적이다.
축방향 분산 계수는 맥동의 진폭의 제곱과 진동수에 비례하는 것으로 나타났고 액상의 유속은 별로 영향을 끼치지 않았다. 단, 맥동이 약한 경우에는 탑내에서 유체의 순환과 편류 현상이 일어났다.
판의 구조의 영향을 살피기 위하여 형태와 자유 행로 면적이 크게 다른 판을 사용하였다. 이때 자유 행로 면적의 증가는 판간의 거리와 마찬가지로 축방향분산을 감소 시켰다.
축 방향 분산계수의 측정은 산과 알칼리의 중화반응을 이용한 방법을 사용 하였으며, 실험상관식은 다음과 같다.
$E = 0.382S^{-1.78}H^{0.38} + 0.364S^{-1.58}H^{-0.58}A^2f$