The behavior of near-wall bubbles in subcooled flow boiling has been investigated photographically to identify the physical mechanisms of critical heat flux at subcooled and low-quality conditions. Visualization experiments were performed for water flow in vertical rectangular channels under atmospheric pressure for mass fluxes below 2020 kg/㎡s. The thickness and other features of the near-wall bubble layer were examined with the aid of a high-speed camera, a still camera and an 8 mm-camera recorder. The number of activated nucleation sites increased as the wall heat flux was increased. At sufficiently high heat flux about 5-7.5 MW/㎡, the appearance of vapor clot or blanket on the heated surface made a role of an obstacle between main liquid region and the region near heater. At such high heat flux, three characteristic regions were observed in the heated channel: (a) a superheated liquid layer with attached bubbles, (b) a flowing bubble layer consisting of large coalesced bubbles over the attached bubbles, and finally (c) the liquid core.
미포화, 저건도 영역 임계 열유속의 물리적 메커니즘을 확인하기 위해 가시화를 통한 미포화 유동 가열면 근처 기포들의 거동에 대한 연구가 수행되었다. 가시화 실험은 수직 사각관에 대하여 물을 작동 유체로 사용하여 수행되었다. 압력은 대기압이며, 질량유속은 2020 kg/㎡ 이하에서 수행되었다. 고속 카메라와 스틸카메라, 8 mm 캠코더를 사용하여 벽면 기포층의 두께와 다른 특징 들이 조사되었다. 활성화된 핵생성 지점의 수는 열유속의 증가에 따라 늘어났다. 벽면 기포들의 성장과 큰 기포들의 군집현상이 관찰되었다. 약 5-7.5 MW/㎡의 고열유속에서, 차단 기포(Vapor Blanket)들은 액체층과 벽면 근처 영역 사이에 액체 흐름에 대한 방해물로서 존재하였다. 이러한 고열유속에서, 유동 채널을 통해 3개의 특징적인 영역이 관찰되었다: (a) 가열면에 고착되어 있는 기포들을 지닌 과열 액체 층, (b) 고착된 기포위로 지나가는 큰 차단 기포(Vapor Clot or Blanket)들을 포함하는 유동 기포 층,(c) 액체 중심 층.