분무식 냉각탑의 기초 설계에 관한 연구 = Preliminary design consideration of spraying-type cooling towers
서명 / 저자 분무식 냉각탑의 기초 설계에 관한 연구 = Preliminary design consideration of spraying-type cooling towers / 서동은.
발행사항 [대전 : 한국과학기술원, 1999].
Online Access 원문보기 원문인쇄

소장정보

등록번호

8009511

소장위치/청구기호

학술문화관(문화관) 보존서고

MME 99028

휴대폰 전송

도서상태

이용가능(대출불가)

사유안내

반납예정일

리뷰정보

초록정보

In the present study, the concept of the spraying-type cooling towers is discussed, and then the preliminary design procedure of spraying-type cooling towers is provided. The spraying-type cooling towers are characterized by the spray-induced air draft to exchange heat and mass transfer between water (to be cooled) and the ambient air. In other words, instead of installing a large fan in the system, an array of spray nozzles is placed at the air-intake to induce the external air for cooling of water. Thus, the spraying-type cooling towers have a merit of low noise and vibration compared to the forced draft cooling towers with a large fan. Generally, the main parameters to be considered in the design procedure are the specifications of the unit nozzles, configuration of the nozzle arrangement, injection pressure and temperature of water, and the ambient-air temperature and humidity. Once the specifications of the nozzles and their arrangements, and the injection conditions are given, the spray performance (such as drop size distribution and the spray pattern) can be decided. Then the amount of the air-draft is determined from the momentum exchange between the spray drops and the ambient air. At the same time, the change of the drop temperature can be determined from the heat and mass transfer between the spray drops and the ambient air. A simplified analysis has been performed to estimate the change of the water(drop) temperature with the axial distance from a nozzle for various injection and ambient air conditions. In the latter part of the present study, the performance of the spray from a unit nozzle was studied experimentally, and also the spray(drop) temperature was measured along the axial direction by changing the injection and the ambient air conditions. Fan spray nozzles widely adopted in the spraying-type cooling towers were used in the experiments. The analytical results reasonably agree with the experimental ones. Finally, the validity of the simplified analytical approach for the preliminary design of the spraying-type cooling was discussed along with the future works.

서지기타정보

서지기타정보
청구기호 {MME 99028
형태사항 viii, 46 p. : 삽화 ; 26 cm
언어 한국어
일반주기 저자명의 영문표기 : Dong-Eun Seo
지도교수의 한글표기 : 이상용
지도교수의 영문표기 : Sang-Yong Lee
학위논문 학위논문(석사) - 한국과학기술원 : 기계공학과,
서지주기 참고문헌 : p. 32-34
QR CODE

책소개

전체보기

목차

전체보기

이 주제의 인기대출도서